Free HP HPE0-S59 Exam 2023 Practice Materials Collection
HPE0-S59 Exam Info and Free Practice Test All-in-One Exam Guide Jan-2023
NEW QUESTION 21
Your customer is implementing an HPE Synergy solution based on three frames.
Click each of the ports that can be used to connect satellite modules.
Answer:
Explanation:
NEW QUESTION 22
Your customer wants to compare HPE Superdome Flex with HPE Superdome Flex 280.
Which statement about these two systems is true?
- A. Only HPE Superdome Rex 280 can be managed using HPE OneView
- B. Only HPE Superdome Flex supports 32 sockets and 48TB of memory
- C. Only HPE Superdome Flex 280 can support multiple nPars
- D. Only HPE Superdome Flex supports HPE Persistent Memory
Answer: A
NEW QUESTION 23
Click the option that will allow you to change the ESXI image used In an OS Deployment Plan.
Answer:
Explanation:
NEW QUESTION 24
Which statement about a new HPE SimpliVity deployment is true?
- A. All new HPE SimpliVity models support deduplication and compression
- B. New HPE SimpliVity deployments are licensed per node not per physical socket
- C. All new HPE SimpliVity models are based on AMD CPUs
- D. New HPE SimpliVity deployments give customer flexible choice of hypervisor
Answer: A
NEW QUESTION 25
Your customer plans to deploy ESXi systems to HPE Synergy and HPE ProLiant servers using HPE OneView for VMware vCenter Server.
Which statement about HPE OneView for VMware vCenter Server functionality is true for this environment?
- A. HPE ProLiant servers need an HPE OneView for VMware vCenter Server license for full functionality
- B. Only systems managed using HPE Oneview can use HPE Oneview for VMware vCenter Server functionalities
- C. HPE Synergy requires HPE Composer 2 for full functionality of HPE OneView for VMware vCenter Server
- D. Individual systems can be added to HPE OneView for VMware vCenter Server through an ILO management processor
Answer: A
NEW QUESTION 26
Your customer needs to move an application from an HPE Synergy 480 Gen10 Compute Module to an HPE Synergy 660 Gen 10 Compute Module. The 480 has a switch that has been manually zoned outside of HPE OneView.
What must the customer do before migrating the application?
- A. Edit the server profile and change server hardware type
- B. Copy the server profile and assign the clone to the new hardware
- C. Create a new server profile template and apply to the new hardware
- D. Migrate the application to a Logical JBOD and connect it to the new server
Answer: A
NEW QUESTION 27
Which tool can be used to evaluate me health of an HPE Oneview appliance before proceeding with an appliance updated.
- A. HPE OneView Update Readiness Checker
- B. HPE OneView Global Dashboard
- C. HPE OneView Firmware Compliance Report
- D. HPE Composer Maintenance Console
Answer: D
NEW QUESTION 28
Your customer plans to deploy HPE OneView for VMware vCenter Server together with HPE Storage Integration Pack for VMware vCenter. The customer wants to use them to manage HPE Synergy Gen10 compute modules. HPE ProLiant Gen 10 servers and an MSA array.
Which statement about compatibility of the existing environment with the planned software components is true?
- A. To use the required plugins HPE ProLiant Gen10 systems must be managed using HPE OneView
- B. HPE OneView for VMware vCenter Server does not support standalone HPE ProLiant servers
- C. Both HPE Synergy Gen10 full-height compute module plugins will require a license
- D. HPE Storage integration Pack for VMware vCenter does not support MSA arrays
Answer: B
NEW QUESTION 29
A logical interconnect group can span on multiple HPE Synergy frames for which interconnect type?
- A. HPE virtual Connect SE 32 Gb FC Module for Synergy
- B. Brocade 32GB Fibre Channel Switch Module for HPE Synergy
- C. HPE Virtual Connect SE 100 Gb F32 Module tor Synergy
- D. HPE Synergy 12 Gb SAS Connection Module
Answer: C
NEW QUESTION 30
Your customer plans to use HPE Primera to boot HPE Synergy compute nodes. They currently have two HPE Virtual Connect SE 100Gb F32 Module for Synergy modules installed in the frame. The customer wants to use FC as a storage access protocol What must be done to complete this task?
- A. Enter both modules into a maintenance mode, then enable FC connectivity through CLI
- B. FC connectivity on the modules should be enabled through the service console by disabling FCoE.
- C. Add FC upgrade licenses in HPE OneView that will enable FC connectivity for the modules
- D. Enable FC primary and secondary boot on the modules through the HPE OneView interface
Answer: B
NEW QUESTION 31
Your customer plans to deploy HPE Superdome Flex and configure two nPars, each based on two chassis Which components must be included in the proposal to meet the customer's needs?
- A. At least Tour HPE Persistent Memory DIMMs per nPar
- B. One base chassis and three expansion chassis with licenses
- C. HPE Superdome Flex Grid licenses enabling connectivity between chassis
- D. Rack Management Controller for nPar management
Answer: B
NEW QUESTION 32
Your customer plans to deploy VMware ESXi 7 0 U2 and they are looking for a hardware platform mat wilt allow them to use up to 24 TB of physical memory.
Which HPE compute system meets this customer's requirements?
- A. HPE ProLiant DL560 Gen10
- B. HPE ProLiant DL380 Gen 10 Plus
- C. HPE Synergy 480 Gen10 Plus
- D. HPE Superdome Flex 280
Answer: B
NEW QUESTION 33
You are troubleshooting an HPE OneView server profile that presents a critical state. The server profile was configured with a Link Aggregation Group What should you check to fix the issue?
- A. if both FiexNICs are connected to different networks
- B. if the logical enclosure is configured with redundant master modules
- C. if both FiexNICs are configured with the same speed
- D. If the logical enclosure is built on at least three HPE Synergy frames
Answer: C
NEW QUESTION 34
Your customer reports mat an external FC boot volume for Windows server is visible four times in the Disk Management 1 online and 3 offline.
What should you do to resolve this issue?
- A. Install and configure MPIO on me Windows system
- B. Disable deduplication for this volume at the array level
- C. Remove the offline disks using Windows Disk Management
- D. Remove the offline disks using array management tools
Answer: A
NEW QUESTION 35
Your customer wants to add dedicated Fibre Channel connectivity to the HPE Synergy frame running HPE Synergy 480 Gen10 compute modules, each with one CPU socket populated Currently they use two 12 Gb SAS switches and two HPE Virtual Connect SE 100Gb F32 Modules for HPE Synergy installed in third fabric.
What must be done to enable dedicated FC connectivity for this HPE Synergy frame?
- A. For VC-FC modules, all of server facing ports must be property licensed.
- B. For Brocade switches, a logical interconnect group must be created in HPE OneView.
- C. SAS switches must be moved to second fabric and FC modules Installed in the first one.
- D. A second CPU must be installed for all HPE Synergy 480 Gen10 compute nodes.
Answer: C
NEW QUESTION 36
Which HPE Virtual Connect feature allows an administrator to suppress excessive inbound multicast broadcast and destination lookup failure (OLF) packets?
- A. LLDP tagging
- B. Storm control
- C. Loop protection
- D. Pause flood protection
Answer: B
NEW QUESTION 37
......
Pass HP HPE0-S59 Actual Free Exam Q&As Updated Dump: https://www.passleadervce.com/HPE-Technical/reliable-HPE0-S59-exam-learning-guide.html
Latest HPE0-S59 Actual Free Exam Updated 60 Questions: https://drive.google.com/open?id=1nUAsPGq-P1qu_ldYIQOBn-iPNopM8TNC