Pass Guaranteed Quiz 2024 Realistic Verified Free D-PE-OE-23 Exam Dumps
Free DECA-PowerEdge D-PE-OE-23 Ultimate Study Guide (Updated 325 Questions)
NEW QUESTION # 169
Which component of the Dell EMC PowerEdge server provides system information, status, and error messages to indicate when the system is operating correctly, or when the system needs attention?
- A. RACADM
- B. Front Panel LCD
- C. BIOS
- D. UEFI
Answer: B
NEW QUESTION # 170
A technician working with a Dell EMC PowerEdge 1 take corrective action?
- A. Check the LCC Log
Check PSU LED
Reseat the PSU - B. Check the System Event Log
Check PSU LED
Reseat the PSU - C. Check the LCC Log
Check PSU LED
Reseat the CPU - D. Check the System Event Log
Check PSU LED
Do a virtual reseat of the iDRAC
Answer: D
NEW QUESTION # 171
A technician is experiencing a compatibility issue that causes network disconnects between the iDRAC firmware and an application that is running.
The iDRAC must be rolled back to the last working version. The Enterprise licensed server cannot be rebooted outside scheduled maintenance windows. The next scheduled window is one month away.
Where should the technician perform the Firmware Rollback?
- A. Repository Manager
- B. Lifecycle Controller
- C. iDRAC GUI
- D. Dell System Update Utility
Answer: C
NEW QUESTION # 172
Which component of the Dell EMC PowerEdge 13G server can be used as an indicator to locate a specific system within a rack?
- A. LCD Front Panel
- B. Back Panel
- C. iDRAC8
- D. System ID button
Answer: D
NEW QUESTION # 173
Where is the data stored to allow Easy Restore to successfully complete a system board replacement?
- A. IDSDM card
- B. Internal USB flash
- C. Front control panel
- D. BOSS
Answer: C
NEW QUESTION # 174
In which Dell EMC PowerEdge server generation was the BOSS card introduced?
- A. 12G
- B. 14G
- C. 13G
- D. 15G
Answer: B
NEW QUESTION # 175
Which iDRAC menu includes the detailed log files required to troubleshoot a hardware issue on a Dell EMC PowerEdge server?
- A. Diagnostics
- B. Troubleshooting
- C. Maintenance
- D. System
Answer: C
NEW QUESTION # 176
A technician wants to move memory from a few older system into a newer system.
What is the most efficient method for the technician to accomplish this task?
- A. Power down all of the older servers to physically check the memory. Move any matching memory to the new server.
- B. Back up the server profile on the older server, move the matching memory, and import the server profile to the new server
- C. Power down any of the older servers to move any memory to the new server, update BIOS to allow mis-matched memory.
- D. Use iDRAC to view the memory details of the older systems. Power down the servers to move matching memory to the new server
Answer: C
NEW QUESTION # 177
Where is the data stored to allow Easy Restore to successfully complete a system board replacement?
- A. Serial Flash storage in the server's front panel
- B. vFlash SD card
- C. IDSDM SD card
- D. NAND Flash module on the disk drive mid plane
Answer: B
NEW QUESTION # 178
A technician needs to configure a server to PXE boot a server setup image with the BIOS in UEFI mode.
What action is required to enable this function?
- A. Navigate to Network Settings, PXE Device1 Settings, and configure IP
- B. Boot to Ctrl+S and configure the NIC for PXE Device1
- C. From the iDRAC web interface, select Network Settings, and enable PXE Device1
- D. Navigate to Boot Options Settings and set PXE Device1 as first option
Answer: D
NEW QUESTION # 179
A new server with default iDRAC network configurations is plugged into a segregated management network configured for 10.0.0.x/24. The technician cannot connect to the iDRAC.
How can the on-site technician configure the iDRAC for network access?
- A. Configure a DHCP reservation for the iDRAC MAC address
- B. Perform an AC power cycle to reset the iDRAC
- C. Change iDRAC network settings from a workstation on the management network
- D. Modify the iDRAC settings using the iDRAC Direct feature
Answer: D
NEW QUESTION # 180
Which mobile devices are supported by Quick Sync 2.0 in 14G PowerEdge servers?
- A. iOS, Android, and Windows Phone devices
- B. iOS devices only
- C. Android devices only
- D. iOS and Android devices only
Answer: D
NEW QUESTION # 181
A technician needs to install the OS on a server remotely using iDRAC.
What is the minimum iDRAC license required to perform this task?
- A. Enterprise
- B. Basic
- C. Baseboard Management Controller
- D. Express
Answer: A
NEW QUESTION # 182
A technician is tasked to perform a RAID Level Migration (RLM) of a RAID 5 array to a RAID 6 array.
The technician backs up data and looks in OpenManage Server Administrator to find that the current RAID 5 array is sliced into two virtual disks.
What should the technician do to achieve the desired RAID level?
- A. Delete the RAID 5 array and complete RLM using iDRAC GUI under Storage > Virtual disks
- B. Delete the arrays and recreate new RAID 6 arrays
- C. Use iDRAC GUI under Storage > Virtual disks to complete RLM
- D. Use SupportAssist for Servers to complete RLM
Answer: B
NEW QUESTION # 183
A Dell EMC PowerEdge 14G server uses Intel OPTANE DC Persistent Memory in Memory mode.
What is the minimum size DIMM supported for this type of memory?
- A. 64 GB
- B. 256 GB
- C. 128 GB
- D. 512 GB
Answer: C
NEW QUESTION # 184
Match each RAID level to its characteristic.
Answer:
Explanation:
NEW QUESTION # 185
What is the purpose of the Silicon-Based Hardware Root of Trust feature in Dell EMC PowerEdge
14G servers?
- A. Ensures that the installed operating system is authentic
- B. Ensures that the server has a valid Service Tag number
- C. Ensures that no unauthorized BIOS or firmware codes are run
- D. Ensures that the server boots only when connected to a verified network
Answer: C
NEW QUESTION # 186
A technician has received a new server with 5 drives and needs to configure the drives into a specific configuration as provided by the administrator.
The administrator will also add additional disks as separate raid arrays at a later date.
- Drive 0 is passed through to the OS (to be managed by the OS)
- Drives 1-3 as a RAID 5 with drive 4 as a hot spare just for this newly created RAID 5 How should the technician do this in the PERC BIOS?
- A. Set drive 0 to Ready, set drives 1-3 as a RAID 5, and drive 4 as a Global Hot Spare
- B. Set drive 0 to Ready, set drives 1-3 as a RAID 5, and drive 4 as a Dedicated Hot Spare
- C. Set drive 0 to Non-Raid, set drives 1-3 as a RAID 5, and drive 4 as a Dedicated Hot Spare
- D. Set drive 0 to Non-Raid, set drives 1-3 as a RAID 5, and drive 4 as a Global Hot Spare
Answer: C
NEW QUESTION # 187
A technician has a server with the following memory configuration:
- Sixteen 4 GB dual-rank DIMMs
- 8 GB available to the OS
The workload intended for the server required the memory configuration to protect against some errors.
Now the technician must deploy for a different workload that requires access to all available memory.
Which setting should the technician change to make all memory available to the system?
- A. Sparing
- B. Optimizer
- C. Performance
- D. Mirrored
Answer: D
NEW QUESTION # 188
What is the purpose of the ePSA on a Dell EMC PowerEdge server?
- A. System diagnostics before starting the operating system
- B. External PowerEdge support assist
- C. System diagnostics while the operating system is running
- D. Centralized PowerEdge support assist
Answer: A
NEW QUESTION # 189
SPECIAL INSTRUCTIONS
The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens. When displaying a question, you can easily review the related case study by clicking on the 'Review Case Study icon shown below:
Case Study 5 - Refer to the Exhibit.
Backing up data from a Dell EMC Isilon cluster exceeds the company's backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes.
Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC Net Worker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.
The company's IT team is now looking for a new data protection strategy.
The company wants to:
- Minimize the backup window
- Increase the speed of data recovery
- Reduce the network traffic
- Reduce the overall growth of the backup datasets
The IT Team indicates that their currently backup hardware will be used in any solution.
Which solution meets their requirements?
- A. Implement an incremental forever backup strategy
- B. Configure the DMA to use IPv6 for better performance
- C. Increase the backup tape block size to 512 KB
- D. Change the backup strategy to token-based backups
Answer: A
NEW QUESTION # 190
......
Get to the Top with D-PE-OE-23 Practice Exam Questions: https://www.passleadervce.com/DECA-PowerEdge/reliable-D-PE-OE-23-exam-learning-guide.html
Use Real D-PE-OE-23 Dumps Free Sample Questions and Practice Test Engine: https://drive.google.com/open?id=1w9Bc_nrnBtU_O7P2gdgqItZjktdhYK7N